Shielding Integrity Services provides expert NSIL Chamber Validation to confirm your Semi-Anechoic Chamber (SAC) meets the essential performance criteria required for compliant low-frequency radiated emissions testing. This critical evaluation guarantees your chamber provides accurate and reliable data in the 9 kHz to 30 MHz range, adhering strictly to official standards.
Test Purpose & Standards
The Normalized Site Insertion Loss (NSIL) test confirms your Semi-Anechoic Chamber (SAC) meets the essential performance criteria required for compliant low-frequency radiated emissions testing.
Accreditation Standard
- CISPR 16-1-4 (The specific edition and year will be noted in your report.)
Technical Specifications & Methodology
The NSIL measurement is a rigorous test involving magnetic field measurements inside the chamber.
Frequency & Range
- Frequency Range: 9 kHz – 30 MHz (Critical for low-frequency emissions).
- Test Distance: Performed at 3-meter or 10-meter distances.
Measurement Methodology
Our NSIL measurement is an adaptation of the NSA procedure, using specialized H-field (magnetic field) loop antennas. Performance is demonstrated using loop antennas in three orthogonal orientations: Hx, Hy, and Hz.
SIS Expertise: Accuracy and Efficiency
SIS brings decades of practical experience to every NSIL validation. We ensure that every data point is accurate and compliant with your requirements.
Accurate Data Capture
- Our team leverages state-of-the-art equipment and patented, automated data capture software to increase accuracy and save you time.
- We provide quick troubleshooting and expert analysis to help you meet the required chamber performance quickly.
- NSIL testing is typically validated across SAC and Open Area Test Sites (OATS).
Full Chamber Lifecycle Support
We perform NSIL validation on all chamber stages and sizes globally:
- New Chambers: Validating newly installed facilities.
- Existing Chambers: Re-validating for ongoing performance assurance.
- Modified Chambers: Testing after upgrades, modifications, or relocation.
- Chamber Size: Capable of testing small, compact 3-meter chambers to high-performance, fully compliant 10-meter chambers.