CISPR 16-1-4 Assessment: Set-up Table Influences (TI) Testing
Don’t settle for testing that adds complexity and risk to your schedule. Shielding Integrity Services (SIS) delivers expert, fully accredited, independent CISPR 16-1-4 Assessment based on decades of practical, hands-on experience—not just theory. We use state-of-the-art automated systems that maximize testing efficiency, ensuring fast turnaround of accurate data and quick troubleshooting for any required performance adjustments. Whether validating a compact 3-meter setup or a specialized 10-meter facility anywhere in the world, SIS delivers the precise, compliant results you need to confidently move your projects forward.ward.
Test Necessity & Standards
The Set-up Table Influences (TI) test is a critical evaluation designed to determine the subtle influence a set-up table has on field strength measurements. This ensures that the table itself does not contribute unacceptable errors to your test results, which is vital for maintaining compliance integrity.

Accreditation Standard
- We perform this evaluation as described in CISPR 16-1-4 (2010), Clause 5.5.2.
Measurement Methodology: Dual-Measurement Integrity
Our precise methodology isolates the table’s influence, providing a direct measurement of its impact on your testing environment.
Procedure: Two-Step Isolation
- We conduct two transmission measurements: one with the set-up table present, and the second with the set-up table absent.
- During both measurements, the transmit antenna is kept in the same specific arrangement.
- The difference between the two measurement results provides a highly accurate estimate of the influence caused solely by the table.

Detailed Frequency Ranges & Measured Results
This specialized test covers a wide range necessary for comprehensive EMC validation and provides actionable, clear data for your records.
Test Parameters
- Frequency Range: The test is performed for the 200 MHz to 18 GHz frequency range.
- Report Output: Following the test, we issue a report detailing the table value in dB for the following ranges:
- 200 MHz to 1 GHz
- 1 GHz to 6 GHz
- 6 GHz to 18 GHz
Estimating Uncertainty Contribution
One of the most important aspects of this service is its contribution to validating the overall test environment’s reliability.
- We calculate the table’s related uncertainty contribution to your field strength measurements, ensuring your compliance reporting is complete and accurate.