Reverberation Chamber Field Uniformity Testing
Don’t settle for testing that adds complexity and risk to your schedule. Shielding Integrity Services (SIS) delivers expert, fully accredited, independent Reverberation Chamber Testing based on decades of practical, hands-on experience. proven, reliable test equipment and automated measurement systems that meet applicable industry standards and maximize testing efficiency, ensuring fast turnaround of accurate data and quick troubleshooting for any required performance adjustments. Wherever your facility is located, SIS delivers the precise, compliant results you need to move your projects forward with confidence.
Test Objectives
Reverberation chambers (mode-stirred/mode-tuned chambers) require specialized validation to ensure a statistically uniform electromagnetic field is generated throughout the working volume. This guarantees your Equipment Under Test (EUT) is exposed to a consistent, standardized field from all directions.
Technical Specifications
We leverage advanced automation to handle the complex, high-density data capture required for reverb testing.
- Our software collects and calculates the necessary fields to determine field uniformity, maximum field strength, and chamber calibration factors across your specified frequency spans and step sizes.
- Testing can be performed in both Loaded and Unloaded configurations depending on the level of verification needed.
Methodology
Validating a reverberation chamber is distinctly different from anechoic chamber testing. Our expert technicians verify the chamber’s ability to support an adequate number of resonant modes.
- Field Uniformity: We measure the field strength at eight locations (the corners of the working volume) over a complete rotation of the tuner(s).
Standards & Performance
Validation is performed in accordance with IEC 61000-4-21, providing you with fully accredited, independent verification of your facility’s performance.